Introduction: Self-reported biometric values, such as blood pressure (BP), have been proposed as an efficient strategy for monitoring clinical care, evaluating health system performance, and conducting pragmatic randomized trials. There is limited evidence about whether self-reported biometric readings are accurate and, if so, whether their accuracy is predicted by readily identifiable patient characteristics.

Objective: Using data from the ongoing Medication adherence Improvement Support App For Engagement – Blood Pressure (MedISAFE-BP), the concordance of self-reported BP > 140mmHg systolic was compared to measured BP > 140mmHg.

Methods: Subjects were recruited through online patient communities, social media, and targeted advertisements; those who indicated their BP was poorly controlled while on medication underwent further screening. Subjects were then mailed a home BP cuff to verify their selfreported blood pressure. We evaluated the positive predictive value of self-reported poorly controlled hypertension using the measured BP readings. We then used multivariable logistic regression to identify predictors of having a measured BP value that was actually poorly controlled.

Results: 1,142 individuals self-reported poorly controlled BP. The positive predictive value of poorly-controlled BP by self-report was only 37%; with 284 (24%) subjects having systolic BPs that were normal (systolic BP < 120 mmHg). Factors that were independently associated with accurate self-report included older age (odds ratio [OR] 1.3 per decade, 95% confidence interval [CI] 1.2-1.5), a history of prior stroke (OR 2.5, CI 1.2-5.2), diabetes mellitus (OR 1.5, CI 1.1-2.2), and a low level of activation (OR 1.63, CI 1.2- 2.2). Hypertension knowledge, education, and self-reported adherence were not associated with accurately selfreporting BP.

Discussion: In this cohort of individuals who reported that their BP was poorly control, only one-third actually had elevated BP when measured with a home BP cuff. While this discrepancy may have many underlying causes, it suggests that the use of self-reported BPs is not an accurate method of monitoring hypertension control at the population-level. Reassuringly, several factors are independently associated with accurate self-reported BPs, and thus there may be some subgroups for whom self-report can be relied upon.

Further reading

Aug 08 2019

Chan R, Jankovic F, Marinsek N, Foschini L, Kourtis L, Signorini A, Pugh M, Shen J, Yaari R, Maljkovic V, Sunga M, Hee Song H, Joon Jung H, Tseng B, Trister A

Source: KDD 2019

Jun 06 2019

Bakker JP, Goldsack JC, Clarke M, Coravos A, Geoghegan C, Godfrey A, Heasley MG, Karlin DR, Manta C, Peterson B, Ramirez E, Sheth N, Bruno A, Bullis E, Wareham K, Zimmerman N, Forrest A, Wood WA

Source: NPJ Digital Medicine